Skip to content

16.4.5 tagmetaimport

tagmetaimport imports TAG table metadata in bulk from CSV. Use it to register large numbers of tag names and metadata values. It does not automatically update existing tags or apply the entire file as one transaction.

Options

tagmetaimport -h
OptionDescription
-s, --server=SERVERServer IP address (default: 127.0.0.1)
-P, --port=PORTServer port (default: 5656)
-u, --user=USERUsername (default: SYS)
-p, --password=PASSWORDUser password (default: MANAGER)
-t, --table=TABLE_NAMETarget metadata storage table. For logical table sensor_tag, specify _SENSOR_TAG_META
-d, --data=DATA_FILEMetadata CSV path
-l, --log=LOG_FILELog file path
-b, --bad=BAD_FILEFile for failed input records
-H, --headerTreat the first CSV row as a header
-D, --delimiter=DELIMITERField delimiter (default: ,)
-E, --encoding=CHARSETFile encoding (default: UTF8)
-I, --silentReduce progress output. Check success/failure counts in the completion summary
-h, --helpDisplay options

Input File Format

Arrange CSV columns in the same order as the TAG table’s metadata columns.

Example TAG table definition:

CREATE TAG TABLE sensor_tag (
    name   VARCHAR(64) PRIMARY KEY,
    time   DATETIME    BASETIME,
    value  DOUBLE      SUMMARIZED
) METADATA (
    unit   VARCHAR(32),
    location VARCHAR(128)
);

Metadata CSV for this table (tag_meta.csv):

name,unit,location
sensor_001,celsius,Building-A Floor-1
sensor_002,celsius,Building-A Floor-2
sensor_003,bar,Boiler-Room
sensor_004,rpm,Motor-Section

Data without a header:

sensor_001,celsius,Building-A Floor-1
sensor_002,celsius,Building-A Floor-2

Examples

Basic Import

tagmetaimport -s 127.0.0.1 -P 5656 -u SYS -p MANAGER \
    -t _SENSOR_TAG_META -d tag_meta.csv -H

Importing CSV with a Header

tagmetaimport -s 127.0.0.1 -P 5656 -u SYS -p MANAGER \
    -t _SENSOR_TAG_META -d tag_meta.csv -H

Importing to a Remote Server

tagmetaimport -s 192.168.0.10 -P 5656 -u SYS -p MANAGER \
    -t _SENSOR_TAG_META -d tag_meta.csv -H

Tab-delimited Files

tagmetaimport -s 127.0.0.1 -P 5656 -u SYS -p MANAGER \
    -t _SENSOR_TAG_META -d tag_meta.tsv -D '\t' -H

EUC-KR Files

tagmetaimport -s 127.0.0.1 -P 5656 -u SYS -p MANAGER \
    -t _SENSOR_TAG_META -d tag_meta_kr.csv -E MS949 -H

Behavior

  • -t does not automatically convert a logical TAG table to its METADATA target. For logical table sensor_tag, specify _SENSOR_TAG_META. Use this name only to select the tool’s ingestion target.
  • Existing tag names cause ordinary METADATA INSERT errors. Check failure counts and the bad/log files.
  • This tool is efficient for adding metadata after data has already been ingested.
  • For small amounts of metadata, use SQL INSERT or enter statements directly in machsql.
-- Insert metadata directly in machsql
INSERT INTO sensor_tag METADATA (name, unit, location)
VALUES ('sensor_005', 'volt', 'Panel-Room');

Notes

  • Create the TAG table before importing.
  • CSV column order must match the TAG table’s metadata column order.
  • Exclude the BASETIME column (time) and SUMMARIZED column (value) from the metadata file.

Change existing values with UPDATE sensor_tag METADATA ... or an explicit SQL UPSERT. For reproducible examples of new ingestion and duplicate ingestion failures, see Bulk Metadata Registration. The server maintains _LAST_UPDATE_TIME when new metadata is inserted or values actually change.